Carrier SDL v6.2
Carrier SDL v6.2 Downloadly IRSpace
The System Design Load (SDL) program calculates design cooling and heating loads for commercial buildings to facilitate HVAC system design. System Design Load advances the art of HVAC load estimating by introducing the concept of system-based design. System-based design is a technique which considers specific HVAC system features when performing load estimating and system sizing calculations. This is important because many systems have unique features which require special sizing procedures. For example, consider Single Zone CAV, VAV, and Fan Powered Mixing Box systems. All contain different components and operate in different ways. To provide high quality system sizing data, the special features of each must be considered when sizing the system.
In the past, HVAC load estimating programs calculated room loads and airflow rates, and system airflow rates and coil loads without considering system specifics. This data is useful for general studies and for preliminary design when the system type is not known. System Design Load still offers these capabilities, but also provides the option of going a step further to tailor system sizing data to specific air handling designs and controls. In System Design Load, general load calculation and system-based design start with the basics. Access to design weather data for thousands of cities is at your fingertips. The ability to define specific wall, roof, and window constructions. Features for defining building design, layout, and operation in as much or as little detail as necessary. The process then continues by allowing the user to specify the type of system and controls used to deliver cooling and heating to the building. As much or as little detail as desired can be used. Sizing procedures then are tailored to the system choice to provide high-quality output listings for room loads and airflow rates, system coil loads and fan airflow rates, and component load details.
Features of Carrier SDL
- System Design Load v6 offers the same 3D building modeling features as HAP v6. Please see the HAP v6 web
- page for more extensive discussion of those features.
- System-based design loads for sizing and selecting system fans, central cooling and heating coils, air terminal
- equipment, space heating coils, preheat coils, and central chiller.
- Uses ASHRAE® Heat Balance cooling load calculation procedure and ASHRAE clear sky solar algorithms.
- Uses ASHRAE procedure for peak heating load calculations.
- Calculates outdoor ventilation airflow rates per ASHRAE Standards 62.1 (2004 though 2019 editions).
- Permits scheduling of cooling and heating equipment operation from 1 to 24 hours per day.
- Performs complete psychrometric analysis with conditions adjusted for altitude.
- Calculates zone and coil loads for 12 monthly design cooling days, and 24 hours per day.
- Searches for maximum zone and cooling coil loads.
- Analyzes sloped roofs and skylights.
- Analyzes building orientations at any of 16 principal exposures.
System Requirements
- Operating System: Windows 10 64-bit or Windows 11 64-bit
- Hard Disk Space: 500 MB
- RAM: 8 GB or greater